戶外真空柱上斷路器
1、概要
ZW32PW-12C/630-20型(xing)室外開(kai)關(guan)(guan)磁阻電(dian)(dian)(dian)機(ji)重力作用漏電(dian)(dian)(dian)斷路(lu)器(之下統稱負荷(he)開(kai)關(guan)(guan))是主(zhu)要用于(yu)三相四線(xian)制(zhi)交流會50Hz,額定值端電(dian)(dian)(dian)壓(ya)為(wei)7.2~12kV輸電(dian)(dian)(dian)應用的野外高電(dian)(dian)(dian)壓(ya)面板開(kai)關(guan)(guan)機(ji)械設(she)備。負荷(he)開(kai)關(guan)(guan)選擇稀土(tu)永磁操主(zhu)觀因素構,與CFT-210型(xing)或(huo)CMC-3L型(xing)等管(guan)控最終和PT(電(dian)(dian)(dian)源(yuan)開(kai)關(guan)(guan)供(gong)電(dian)(dian)(dian)變(bian)壓(ya)器)來組成(cheng)部(bu)分自動(dong)(dong)式化型(xing)負荷(he)開(kai)關(guan)(guan),廣常用性(xing)于(yu)變(bian)電(dian)(dian)(dian)器站饋線(xian)最終、工(gong)業企(qi)業公(gong)司供(gong)電(dian)(dian)(dian)電(dian)(dian)(dian)纜(lan)線(xian)及城、農(nong)網輸供(gong)電(dian)(dian)(dian)裝置作護理和管(guan)控,特意常用性(xing)于(yu)工(gong)作一直的娛(yu)樂場所(suo)和城、農(nong)網自動(dong)(dong)式化配(pei)輸電(dian)(dian)(dian)絡。
2、功能性優點
高壓(ya)斷路器與CFT-210型調控器積極配(pei)合安全使用(yong)(yong),能夠改(gai)變一下用(yong)(yong)途:
(1)系統(tong)自動腫瘤切除三相變頻器接地極錯誤代碼
當(dang)我(wo)(wo)們支線(xian)(xian)(xian)突發二相接地極(ji)出(chu)現(xian)問(wen)題(ti)時,低(di)壓(ya)斷路器半自(zi)動分閘,要進行隔離出(chu)現(xian)問(wen)題(ti)支線(xian)(xian)(xian),保持良好(hao)變配發電廠及饋線(xian)(xian)(xian)上教育的所有(you)節點我(wo)(wo)們平常(chang)送電。
(2)自(zi)功斷開連接黃(huang)灰不導通出現故障(zhang)
當顧客(ke)(ke)支線的發生兩色燒壞錯誤(wu)時,隔開(kai)(kai)開(kai)(kai)關守護空開(kai)(kai)跳閘后,隔開(kai)(kai)錯誤(wu)方式。錯誤(wu)方式被隔開(kai)(kai),使(shi)饋線上線下(xia)的各(ge)種構成顧客(ke)(ke)及主網免受錯誤(wu)印(yin)象。
(3)高速 精(jing)準定位(wei)電腦故障(zhang)點
業主支線(xian)內(nei)部(bu)內(nei)部(bu)故(gu)章(zhang)容(rong)易造(zao)成萬能(neng)斷(duan)路器分(fen)閘后(hou),僅負責業主停(ting)水,并可拒絕呈報內(nei)部(bu)內(nei)部(bu)故(gu)章(zhang)資料,使電能(neng)機(ji)構能(neng)不斷(duan)知(zhi)道安全生產事故(gu)點職位,立(li)刻來實地正確處理,使內(nei)部(bu)內(nei)部(bu)故(gu)章(zhang)電纜線(xian)應及早恢愎(bi)電力。
(4)監察我們容載
掌握器(qi)達成(cheng)網絡通訊接口標準,配選重要的(de)(de)附近,可將(jiang)萬能斷路器(qi)執(zhi)行數據(ju)源傳輸電量管(guan)理方法中間,達成(cheng)對無方負荷率的(de)(de)立(li)即(ji)監測(ce)。
(5)漏電斷路器的守護治療途徑
把控好器讀取手機信號共4個:A相工作電流、B相電壓、C相電壓量、零序電壓量。掌握器能夠 時時監測器所訴搜索量,并與定值完成較為來分辨線路圖出現故障的型,導致完成合理的加工處理。
下表為設計比較(jiao)適中點不同的(de)啟動的(de)方式的(de)守(shou)護清理報告。
3、包括系統參數設置
(1)空氣(qi)開(kai)關(guan)的重要枝(zhi)術(shu)因素(su)
序 號 |
項 目 |
單 位 |
數 值 |
|
1 |
穩定線電壓 |
kV |
12 |
|
2 |
額定(ding)值瞬時電流 |
A |
630 |
|
3 |
額定(ding)頻繁 |
Hz |
50 |
|
4 |
工(gong)頻(pin)耐(nai)沖擊 1min |
干試 |
kV |
42/48(斷(duan)口) |
濕試 |
30 |
|||
5 |
沙塵蠕變(bian)耐(nai)受性電流值(最高值)兩色相間、對地/斷口 |
kV |
75/85 |
|
6 |
額(e)定容量漏電開關(guan)機(ji)流 |
kA |
20 |
|
7 |
載荷系數跳閘(zha)關合工作電流(基(ji)線) |
kA |
50 |
|
8 |
電(dian)機(ji)額(e)定功(gong)率閥值耐受力工作電(dian)流 |
kA |
50 |
|
9 |
4S間歇(xie)接(jie)受電壓 |
kA |
20 |
|
10 |
額定功率工(gong)作無限循(xun)環(huan) |
分-0.3s-合(he)(he)分-180s-合(he)(he)分 |
||
11 |
載荷系(xi)數過(guo)壓電流值開斷機會 |
次 |
30 |
|
12 |
機(ji)誡保(bao)修期 |
次 |
10000 |
(2)高壓斷路器機械設備制造特點(dian)主(zhu)要參數
序 號 |
項 目 |
單 位 |
數 據 |
1 |
觸頭開距 |
mm |
9±1 |
2 |
觸頭超(chao)旅(lv)程(cheng) |
mm |
2.5±1 |
3 |
分閘速度(du)快 |
m/s |
1.1±0.3 |
4 |
送電速率 |
m/s |
0.6±0.2 |
5 |
觸頭送電顛簸時刻 |
ms |
≤2 |
6 |
黃灰中(zhong)心局路(lu)程 |
程度丹頓(dun)半(ban)智能化(hua)以及自動化(hua)科枝較少我司 音樂版(ban)權(quan)其它(ta) 聯系(xi)地址:綿陽(yang)市郫(pi)都區(qu)現代工生產業(ye)港(gang)(gang)港(gang)(gang)通北(bei)四路(lu)520號 通(tong)話聯系通(tong)話:13540687777 傳真機:13540687777 郵編地址:611930 報備號: